Jesse 1 Robinson wrote: >Once again motivated to look for the message in recent OPERLOG. Found >something I did not see a few days ago. This is apparently not the same case >that OP described, but it is an instance of IEC614I SCRATCH FAILED. (There >were a few other cases of the message, always from NDM/ConnectDirect, about >not being able to extend a data set.) This instance looks to be SAF related >according to all the other messages.
Indeed. >ICH408I USER(xxx ) GROUP(xxx ) NAME(xxx, xxx ) >xxx.xxx.BACKUP.G0002V00 CL(DATASET ) VOL(xxx) > INSUFFICIENT ACCESS AUTHORITY > FROM xxx.xxx.* (G) > ACCESS INTENT(ALTER ) ACCESS ALLOWED(NONE ) >IGD17105I CATALOG ERROR WHILE DELETING DATA SET >xxx.xxx.BACKUP.G0002V00 Is your EGN 'Enhanced Generic Naming' for dataset profiles turned on or off? Your xxx.xxx.BACKUP.G0002V00 has 4 qualifiers, but the profile xxx.xxx.* has 3 qualifier. Have a talk with your RACF support. Groete / Greetings Elardus Engelbrecht ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN