DASD only logstreams cannot be shared.  Architectural limitation.

You can get operlog to work w/DASDONLY,  but only for a single system.
There is no benefit to LOGR unless you have a CF.

To save you the work, don't bother w/SMF or LOGREC logstreams either.


HTH,

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Sean Gleann
Sent: Thursday, July 19, 2018 8:04 AM
To: [email protected]
Subject: SYSLOG and LOGR query

I'm trying to use a LOGR logstream to gather the SYSLOG data, but I don't 
appear to be able to make it work...
I believe I've correctly followed all the instructions detailed in the relevant 
section of the "z/OS System Logger" redbook.
Modifying the CFRM policy to add the OPERLOG structure, and then defining the 
associated logstream all appears to have gone OK. For what it's worth, I'm 
working with a system in MONOPLEX mode, so the logstream is defined with 
DASDONLY(YES) specified.
My CONSOLxx member includes "HARDCOPY DEVNUM(OPERLOG) ROUTCODE(ALL)
CMDLEVEL(CMDS) HCFORMAT(CENTURY)", which I *think* is right but I'm not 
absolutely certain.
Then to 'activate' the facility, I used the V OPERLOG,HARDCPY command - which 
again I'm not absolutely certain of.

Whenever I try to use the IEAMDBLG program, it either abends with a U0001 or 
ends with message "MLG003I NORECORDS IN RANGE", depending on the PARM that I 
use.

Can anyone see anything wrong with my work here, please?
I can't be the only one trying to do this, so if any one out there can help at 
all, I'd appreciate it mightily.

Sean

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to