On Mon, 23 Jul 2018 16:32:29 -0400, Tony Thigpen wrote: >Data Set Name . . . : TST.COMPILE.LIBRARY > >General Data Current Allocation > Management class . . : **None** Allocated cylinders : 434 > Storage class . . . : **None** Allocated extents . : 1 > Volume serial . . . : HKYSY0 Maximum dir. blocks : NOLIMIT > Device type . . . . : 3390 > Data class . . . . . : **None** > Organization . . . : PO Current Utilization > Record format . . . : U Used pages . . . . : 16,592 > Record length . . . : 0 % Utilized . . . . : 21 > Block size . . . . : 7040 Number of members . : 1,756 > 1st extent cylinders: 434 > Secondary cylinders : 0 > Data set name type : LIBRARY Dates > Creation date . . . : 2004/05/11 > Referenced date . . : 2018/07/23
I don't think that the characteristics of this data set are the cause of your problem. The IEC020I message says that the problem is with DDNAME STYWRK, DSNAME PROD.HKY.WORK.HSR003B.WK1.S050. I would look at the characteristics of that data set. Also, does TST.COMPILE.LIBRARY contain program HAO07E, and what are the LRECL and BLKSIZE specified in that program? -- Tom Marchant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN