On Mon, 23 Jul 2018 16:32:29 -0400, Tony Thigpen wrote:

>Data Set Name  . . . : TST.COMPILE.LIBRARY
>
>General Data                          Current Allocation
>  Management class . . : **None**       Allocated cylinders : 434
>  Storage class  . . . : **None**       Allocated extents . : 1
>   Volume serial . . . : HKYSY0         Maximum dir. blocks : NOLIMIT
>   Device type . . . . : 3390
>  Data class . . . . . : **None**
>   Organization  . . . : PO            Current Utilization
>   Record format . . . : U              Used pages  . . . . : 16,592
>   Record length . . . : 0              % Utilized  . . . . : 21
>   Block size  . . . . : 7040           Number of members . : 1,756
>   1st extent cylinders: 434
>   Secondary cylinders : 0
>   Data set name type  : LIBRARY       Dates
>                                        Creation date . . . : 2004/05/11
>                                        Referenced date . . : 2018/07/23

I don't think that the characteristics of this data set are the cause of your 
problem. The IEC020I message says that the problem is with DDNAME STYWRK, 
DSNAME PROD.HKY.WORK.HSR003B.WK1.S050. I would look at the characteristics 
of that data set.

Also, does TST.COMPILE.LIBRARY contain program HAO07E, and what are the 
LRECL and BLKSIZE specified in that program?

-- 
Tom Marchant

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to