Hi Tony,

If RPG has specific BLKSIZE maximums, then SMS autochanging BLKSIZE could cause 
this behaviour.

Validate dataset attributes.

On Mon, 23 Jul 2018 12:12:52 -0400, Tony Thigpen <[email protected]> wrote:

>IEC020I 001-4,HSR003B,STEP0017,STYWRK,1818,HKYP05,
>IEC020I PROD.HKY.WORK.HSR003B.WK1.S050
>IEC020I DCB EROPT=ABE OR AN INVALID CODE, AND/OR NO SYNAD EXIT SPECIFIED
>
>We have a contractor working on 'performance issues' with this machine,
>and I am wondering if he has changed something. 
>//STYWRK   DD DSN=PROD.HKY.WORK.HSR003B.WK1.S050,
>//         DISP=(OLD,KEEP,KEEP)

>--
>Tony Thigpen
>

Regards
Bruce

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to