ADRDSSU!  Write up some REXX code to pass in all volsers, etc. You get the idea.

Bob

PRINT TRACKS(0,0) -
    INDYNAM(xxxxxx) -
    ADMIN -
    OUTDDNAME(OUTPUT)

Output:

PAGE 0001     5695-DF175  DFSMSDSS V2R02.0 DATA SET SERVICES     2018.253 09:22
*** TRACK(CCHH)  00000000         R0 DATA  0000000000000000
    COUNT  0000000001040018
 0000  C9D7D3F1 00080000 8000015A 06004A98  60000060 08004A98 00000000          
 *IPL1.......!..¢q-..-..¢q....    *
    COUNT  0000000002040090
 0000  C9D7D3F2 07004AB8 40000006 31004ABE  40000005 08004AA0 00000000 06000000 
 *IPL2..¢.......¢.......¢.........*
 0020  20002F55 00000000 00000000 00000400  00000000 00000000 00000000 00000000 
 *................................*
 0040  00000000 00000000 40404040 40404040  40404040 40404040 40404040 40404040 
 *................................*
 0060  40404040 40404040 40404040 40404040  40404040 40404040 40404040 40404040 
 *................................*
 0080  40404040 40404040 40404040 00000000  00000000                            
 *....................            *
    COUNT  0000000003040050
 0000  E5D6D3F1 E5D6D3F1 D9C5E2D9 F0F14000  00000101 40404040 40404040 40404040 
 *VOL1VOL1XXXXXX..................*
 0020  40404040 40404040 40404040 40404040  40404040 40404040 40404040 40404040 
 *................................*
 0040  40404040 40404040 40404040 40404040  40404040                            
 *....................            *
    COUNT  0000000004001A72
 0000  00080000 8000063A 40404040 F0F04040  00000000 00000380 00000000 00000000 
 *............00..................*
 0020  00000000 00000000 00000000 00000000  00000000 00000000 00000000 00000000 
 *................................*
 0040  00000000 00000000 00000000 00000000  00000000 00000000 000A0000 000140E1 
 *................................*
 0060  000A0000 000150E1 000A0000 0002007B  00000000 00000000 000A0000 000180E1 
 *......&........#................*
 0080  00000000 00000000 00000000 00000000  00000000 00000000 00000000 00000000 
 *................................*
 00A0  TO  019F   SAME AS ABOVE
 01A0  00000000 80000000 00000000 00000C0C  00000000 80000000 00000000 00000C0C 
 *................................*
 01C0  00000000 80000000 00000000 00000B92  00000000 80000000 00000000 00000AB0 
 *...............k................*
 01E0  00000000 00000000 00000000 00000000  00000000 80000000 00000000 00000C0C 
 *................................*
 0200  C9C5C1C9 D7D3F0F0 F0F861F2 F461F1F1  40C8C2C2 F7F7F9F0 000A0000 00000000 
 *IEAIPL0008/24/11.HBB7790........*
 0220  00080000 00000000 000A0000 00000019  00080000 80000AD2 00000000 80000000 
 *.......................K........*



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Dyck, Lionel B. (RavenTek)
Sent: Monday, September 10, 2018 8:55 AM
To: [email protected]
Subject: Re: [EXTERNAL] Re: Report volumes with IPLText

Logic does not work for this site ☹

--------------------------------------------------------------------------
Lionel B. Dyck (Contractor)  <sdg><
Mainframe Systems Programmer – RavenTek Solution Partners


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Richards, Robert B.
Sent: Monday, September 10, 2018 6:40 AM
To: [email protected]
Subject: Re: [EXTERNAL] Re: Report volumes with IPLText

Most shops I have "stopped by at" used a variation  of RES*, IODF*, CAT*, SAE* 
and SAD*.

A lot of SYSRES "00 or 01" volumes too (where SYSRES is your four character 
convention for same).

Bob


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Dyck, Lionel B. (RavenTek)
Sent: Monday, September 10, 2018 7:07 AM
To: [email protected]
Subject: Re: [EXTERNAL] Re: Report volumes with IPLText

Good one 😊

No - we are taking responsibility for a sister data center and the individuals 
who knew where things were have retired without adequate doc. I'm looking to 
find which volumes have ipltext - we know of the ones in active use - just 
curious about others - looking for sad and possible stand alone edit.

--------------------------------------------------------------------------
Lionel B. Dyck (Contractor)  <sdg><
Mainframe Systems Programmer – RavenTek Solution Partners


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Beverly Caldwell
Sent: Friday, September 07, 2018 2:16 PM
To: [email protected]
Subject: [EXTERNAL] Re: Report volumes with IPLText

Don't tell me. Your systems are so reliable you've forgotten where your IPL 
volumes are.!

On Fri, Sep 7, 2018 at 10:36 AM Dyck, Lionel B. (RavenTek) < 
[email protected]> wrote:

> Is there a utility that will display all mounted volumes that have IPL
> Text installed?
>
> ----------------------------------------------------------------------
> ----
> Lionel B. Dyck (Contractor)  <sdg><
> Mainframe Systems Programmer - RavenTek Solution Partners
>
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to