Once your PC-owning address space is active, check the ASCBFLG3 byte (offset x'35' into its ASCB) for the ASCBREUS bit (x'40').
If this bit is not ON, you do not have a reusable address space. I believe that DIAGxx "REUSASID(NO)" parameter can override the REUSASID=YES specification on the MVS START command. DIAGxx REUSASID defaults to "YES" -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Joseph Reichman Sent: Friday, October 12, 2018 10:51 AM To: [email protected] Subject: Re: IEF352I Message Yes Joe Reichman 170-10 73 rd ave Fresh meadows NY 11366 > On Oct 12, 2018, at 5:42 AM, Rob Scott <[email protected]> wrote: > > > Are you starting the PC-owning address space with REUSASID=YES ? > > Are you using RESUABLE=YES on your LXRES? > > > > -----Original Message----- > From: IBM Mainframe Discussion List <[email protected]> On > Behalf Of Joseph Reichman > Sent: Friday, October 12, 2018 4:03 AM > To: [email protected] > Subject: IEF352I Message > > Hi > > > > I am getting IEF352I Message Address space Unavailable from a started > Task when I terminate it via a Modify command > > > > > > I have created PC Routines However since I am using a System Linkage > Table The Documentations says that LXFRE and ETDIS don't apply to > using a system entry > > > > I do use ETDES to destroy the table entry at clean up > > > > The documentation says this is not necessary an error > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > ================================ Rocket Software, Inc. and > subsidiaries ■ 77 Fourth Avenue, Waltham MA 02451 ■ Main Office Toll > Free Number: +1 855.577.4323 Contact Customer Support: > https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fmy.ro > cketsoftware.com%2FRocketCommunity%2FRCEmailSupport&data=02%7C01%7 > CRScott%40ROCKETSOFTWARE.COM%7C304dcb917c9e45bcd5c308d63028403e%7C7954 > 4c1eed224879a082b67a9a672aae%7C0%7C0%7C636749346788124853&sdata=xR > 4Hbrg%2Blhg4RnhLHJPVkSgy1jKMcjAWOHwrARxRtM4%3D&reserved=0 > Unsubscribe from Marketing Messages/Manage Your Subscription > Preferences - > https://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ro > cketsoftware.com%2Fmanage-your-email-preferences&data=02%7C01%7CRS > cott%40ROCKETSOFTWARE.COM%7C304dcb917c9e45bcd5c308d63028403e%7C79544c1 > eed224879a082b67a9a672aae%7C0%7C0%7C636749346788124853&sdata=DSOJP > LNf5Ah7uhtgR0hPzrOu0nThGKkVRyMK%2FH1Mmgg%3D&reserved=0 > Privacy Policy - > https://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ro > cketsoftware.com%2Fcompany%2Flegal%2Fprivacy-policy&data=02%7C01%7 > CRScott%40ROCKETSOFTWARE.COM%7C304dcb917c9e45bcd5c308d63028403e%7C7954 > 4c1eed224879a082b67a9a672aae%7C0%7C0%7C636749346788124853&sdata=IB > sM5vbpjB0q40TwRnL%2B8sE67yXA1dFD8omxvwD15Sk%3D&reserved=0 > ================================ > > This communication and any attachments may contain confidential information > of Rocket Software, Inc. All unauthorized use, disclosure or distribution is > prohibited. If you are not the intended recipient, please notify Rocket > Software immediately and destroy all copies of this communication. Thank you. > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN