I believe COMMNDxx is processed before JES startup. You might want to IPL and 
examine the logs to verify this.

Obviously, JES commands cannot be parsed until JESS is up.
You will need "COM='V XXXX,ONLINE' " as opposed to COM="$VS,V XXXX,ONLINE' "  
(I think I got the syntax correct, I did'nt look it up).

HTH,

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Sankaranarayanan, Vignesh
Sent: Monday, November 19, 2018 8:24 AM
To: [email protected]
Subject: Re: [EXTERNAL] Re: Spool volume

Hi Allan,

So the question is.. will COMMNDxx be parsed first or JES2's parameters..

- Vignesh
Mainframe Infrastructure

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Allan Staller
Sent: 19 November 2018 14:05
To: [email protected]
Subject: [EXTERNAL] Re: Spool volume

There is no problem until JES starts to use the volume.
Once JES has used the volume, it will complain if the volume is not available 
at JES start (not sure of the symtpoms, but it *WILL* complain).

HTH,

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Sankaranarayanan, Vignesh
Sent: Monday, November 19, 2018 5:40 AM
To: [email protected]
Subject: Spool volume

Hello List!

Let's say there is a mod27 volume of unit abcd.
This is available to an LPAR (via IODF), but is defined with OFFLINE=YES, so 
not immediately available at IPL, but can be brought online (vary ad-hoc or via 
COMMNDxx).

Is there any constraint that a spool volume needs to be OFFLINE=NO in the 
IODF.. or is COMMNDxx read before the JES2 startup (JES2's PARMLIB member), 
that an IODF change is not required?

Thank you!

- Vignesh
Mainframe Infrastructure


MARKSANDSPENCER.COM
________________________________
Unless otherwise stated above:
Marks and Spencer plc
Registered Office:
Waterside House
35 North Wharf Road
London
W2 1NW

Registered No. 214436 in England and Wales.

Telephone (020) 7935 4422
Facsimile (020) 7487 2670

https://apac01.safelinks.protection.outlook.com/?url=www.marksandspencer.com&amp;data=02%7C01%7Callan.staller%40HCL.COM%7Cc6533349061148e037aa08d64e2ac11b%7C189de737c93a4f5a8b686f4ca9941912%7C0%7C0%7C636782342908667107&amp;sdata=wKMDoMYydIUpvNUzF3xh5DAmXHTW6aHX0mfCX8K2E1A%3D&amp;reserved=0

Please note that electronic mail may be monitored.

This e-mail is confidential. If you received it by mistake, please let us know 
and then delete it from your system; you should not copy, disclose, or 
distribute its contents to anyone nor act in reliance on this e-mail, as this 
is prohibited and may be unlawful.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to