We have seen this while z13 migration to z14 specially with the cable swaps for 
OSA ICC weren't showing active with SE and eventually with the POR (activate) 
for CEC brought them back online . It wasn't in the list as a activity to do 
but now with every cable swap we added POR activity ...not preferred but it 
bring all clean in one go instead of back and forth doing investigation on 
reasons...

----------------------------------------------------------------------