Here is an example of FCTCs with loopback on multiple machines with multiple 
zSeries OS, then mapped to a single DR machine.

zEC12 is production z/OS and z/VM
z13s is production z/OS
zBC12 is z/VSE
z13 is DR machine

Note, the DR machine has the same FCTCs device addresses, only the CHPids are 
changed. 

 
Connected To    Online to       CDC                                             
                                        
EC12    BC12    z13     D000    D100    D200    E300    A000    RESP    VMP1    
VMT1                    
15      32      32      580     584     588     58C     590     594     598     
59C                     
17      33      34      5A0     5A4     5A8     5AC     5B0     5B4     5B8     
5BC                     
        z13s                                                                    
                        
14      48      33      6780    6784    6788    678C    6790    6794    6798    
679C                    
16      49      35      67A0    67A4    67A8    67AC    67B0    67B4    67B8    
67BC                    
                                                                                
                        
z13s    EC12    z13     ASYS    DSYS    TSYS                                    
                        
48      14      32      6760    6764    6768                                    
                        
49      16      34      6770    6774    6778                                    
                        
                                                                                
                        
BC12    EC12    z13     LPAR1   LPAR2   LPAR3   LPAR4   LPAR5   LPAR6   LPAR7   
LPAR8   LPAR9   VMP2    VMT2
32      15      33      6700    6704    6708    670C    6710    6714    6718    
671C    6720    6724    6728
33      17      35      6730    6734    6738    673C    6740    6744    6748    
674C    6750    6754    6758
                                                                                
                        
z13s    z13s    z13     ASYS    DSYS    TSYS                                    
                        
41      40      36      6400    6408    6410                                    
                        
45      44      37      6800    6808    6810                                    
                        
                                                                                
                        
40      41      56      6420    6428    6430                                    
                        
44      45      57      6820    6828    6830                                    
                        
                                                                                
                        
BC12    BC12    z13     LPAR1   LPAR2   LPAR3   LPAR4   LPAR5   LPAR6   LPAR7   
LPAR8   LPAR9   VMP2    VMT2
55      54      36                                                              
                6620    6624
54      55      37                                                              
                6b20    6b24
57      56      56                                                              
                6660    6664
56      57      57                                                              
                6b60    6b64
                                                                                
                        
EC12    EC12    z13     D000    D100    D200    E300    A000    RESP    VMP1    
VMT1                    
12      10      36      6600    6604    6608    660c    6610    6614    6618    
661C                    
10      12      37      6b00    6b04    6b08    6b0c    6b10    6b14    6b18    
6b1c                    
13      11      56      6640    6644    6648    664c    6650    6654    6658    
665c                    
11      13      57      6b40    6b44    6b48    6b4c    6b50    6b54    6b58    
6b5c                    

Hope that helps. But, developing this FCTCs without a Ficon Director or Switch 
is difficult at best, without HCD

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Sankaranarayanan, Vignesh
Sent: Monday, February 18, 2019 12:55 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: [EXTERNAL] Re: CTC

Hi Jerry,

I’m no longer able to find the free version of HCM. Have used it a few years 
ago, inputting my IOCP and was able to view everything.

When I tried to get it last year, I learned that the msi installer is available 
in a PDS member in z/OS.. so I installed it. But it wouldn’t let me do 
anything.. guess it’s just a client for the paid version of HCM.

Where did the freebie go, I wonder...

– Vignesh
Mainframe Infrastructure

On 18-Feb-2019, at 22:42, Jerry Whitteridge <jerry.whitteri...@ibm.com> wrote:

To be able to make sense of CTC definitions I use HCM downloaded to the PC.
Its the only graphical way to review the connections. I also use HCM to define 
new CTC connections. For all other HCD definitions I prefer using HCD and ISPF.

Jerry Whitteridge
Delivery Manager / Mainframe Architect
GTS - Safeway Account
602 527 4871 Mobile
jerry.whitteri...@ibm.com

IBM Services

IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> wrote on
02/18/2019 06:09:21 AM:

> From: ITschak Mugzach <imugz...@gmail.com>
> To: IBM-MAIN@LISTSERV.UA.EDU
> Date: 02/18/2019 06:09 AM
> Subject: Re: CTC
> Sent by: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU>
> 
> I don't have a specific rexx for the problem, but I can give some tips
form
> daily experience. I do parsing every day, many times a day, for our 
> IronSphere product.  IOCP is using a macro language. so:
> 
>   1. make every macro a single string. continuation is at column 72, the
>   last line in a multi line doesn;t have a comma and a continuation 
> char
at
>   col 762.
>   2. tokenize the string by replacing every equal sign to blank.
>   3. wordpos the keyword you are looking for. of position is not zero,
the
>   value is the next word.
>   4. result may be enclosed in parentheses, separated with commas. know
>   what you are looking for for second level parsing.
>   5. I use a stem to store the single line macro calls at step 1.
> 
> 
> best,
> ITschak
> 
> On Mon, Feb 18, 2019 at 2:32 PM Sankaranarayanan, Vignesh < 
> vignesh.v.sankaranaraya...@marks-and-spencer.com> wrote:
> 
>> Hello All,
>> 
>> I know this is a long shot but does anyone have any REXX that parses
IOCP
>> and "makes sense" of the CTC definitions?
>> I'm losing my mind trying to learn what I'm seeing..
>> 
>> - Vignesh
>> Mainframe Infrastructure
>> 
>> 
>> MARKSANDSPENCER.COM
>> ________________________________
>> Unless otherwise stated above:
>> Marks and Spencer plc
>> Registered Office:
>> Waterside House
>> 35 North Wharf Road
>> London
>> W2 1NW
>> 
>> Registered No. 214436 in England and Wales.
>> 
>> Telephone (020) 7935 4422
>> Facsimile (020) 7487 2670
>> 
>> www.marksandspencer.com
>> 
>> Please note that electronic mail may be monitored.
>> 
>> This e-mail is confidential. If you received it by mistake, please 
>> let
us
>> know and then delete it from your system; you should not copy,
disclose, or
>> distribute its contents to anyone nor act in reliance on this e-mail,
as
>> this is prohibited and may be unlawful.
>> 
>> ---------------------------------------------------------------------
>> - For IBM-MAIN subscribe / signoff / archive access instructions, 
>> send email to lists...@listserv.ua.edu with the message: INFO 
>> IBM-MAIN
>> 
> 
> 
> --
> ITschak Mugzach
> *|** IronSphere Platform* *|* *Information Security Contiguous 
> Monitoring for Legacy **|  *
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to