On Thu, 7 Mar 2019 23:06:55 +0000, Edward Finnell wrote: >I guess the SAFE way is to REJECT it, then do a RECEIVE and
REJECT and RECEIVE isn't necessary or helpful. Reject only removes it from the Global zone. >APPLY S(FMID). You can't APPLY to a target zone that has it already APPLIED unless you REDO. The safe and easy way is to define a new target and distribution zone, with new data sets, and APPLY it. -- Tom Marchant >After the APPLY then go after the remaining >PTFS with APPLY FORFMID(fmid) GROUPEXTEND. >In a message dated 3/7/2019 12:08:56 PM Central Standard Time, >[email protected] writes: >I am in process of reapplying a a product base FMID with SMPE control >cardKeyword REDO. I understand to APPLY REDO I also have to select all the >PTFwhich were already applied to the target zone . >The challenge is i have close to 3k PTF which I have apply along with thebase >FMID. > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN