'//EDIOUT2  EXEC PGM=IDCAMS
//SYSPRINT DD SYSOUT=*
//DDIN     DD DSN=file1,DISP=(OLD,DELETE,KEEP)
//DDOUT1   DD DSN=file2,
//         DISP=(,CATLG),MGMTCLAS=MC60DY,
//         LIKE=file1
//SYSIN    DD DISP=SHR,DSN=PROCLIB(AIBACKC1)   --> sysin is just reporo in to 
out
//*

When these abend with a B37, the DDIN dataset is deleted even though the DISP 
is (OLD,DELETE,KEEP)

XXEDIOUT2, EXEC PGM=IDCAMS
XXSYSPRINT DD SYSOUT=*
XXDDIN     DD DSN=file1,DISP=(OLD,DELETE,KEEP)
IEFC653I SUBSTITUTION JCL - DSN=file1,DISP=(OLD,DELETE,KEEP)
XXDDOUT1   DD DSN=file2,
XX         DISP=(,CATLG),MGMTCLAS=MC60DY,
XX         LIKE=file1
IEFC653I SUBSTITUTION JCL - DSN=file2,DISP=(,CATLG),MGMTCLAS=MC60DY,
LIKE=file1


IEC030I B37-04,IFG0554A,TYC1DABK,EDIOUT2,DDOUT1,C441,OY721C,0426041D,
file2
ESP493I JOB TERMINATED BY CCCHK STOP REQUEST IEF142I TYC1DABK EDIOUT2 STEP02 - 
STEP WAS EXECUTED - COND CODE 0012
IGD106I LOADLIB                    PASSED,    DDNAME=JOBLIB
IEF285I   temp file.D0000227.?         SYSOUT
IGD105I file1                                         DELETED,   DDNAME=DDIN
IGD104I file2  RETAINED,  DDNAME=DDOUT1
IGD104I PROCLIB                          RETAINED,  DDNAME=SYSIN
IEF373I STEP/EDIOUT2 /START 2019200.1222'

----------------------------------------------------------------------