It's also common in some shops for an application to trap something like RC 12 
and issue a user abend just so that conditional disposition gets executed.  

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of CM 
Poncelet
Sent: Tuesday, July 23, 2019 2:53 PM
To: [email protected]
Subject: (External):Re: JCL disp on abend

... and "//DDIN DD DSN=file1,DISP=(OLD,DELETE,KEEP)" states that file1 should 
be deleted regardless on jobstep termination *unless* it abends.

 
On 23/07/2019 06:24, Dan D wrote:
> "IEF142I TYC1DABK EDIOUT2 STEP02 - STEP WAS EXECUTED - COND CODE 0012"
>
> As you can see from the IEF142I the job did NOT abend but rather IDCAMS ended 
> with a return code 12.
>
> Dan


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to