On Thu, 8 Aug 2019 23:52:25 +0100, CM Poncelet wrote:

>FWIW I hesitate to believe that PASSED/DELETED implies that the temp
>datasets were ever physically created on DASD - unless they were OPENed
>for OUTPUT in-between. I think the *physical* alloc happens only on an
>OPEN DCB with MACRF=(PM/L).
> 
>Have you tried something like the following with IEFBR14?
> 
>'//WHATEVER  DD DISP=(,CATLG),                                       
>'//    ...
I don't believe temp data sets can be catalogued.

I'd consider the proof to be whether the data set can be OPENed in a 
later step.  I'd expect a READ to enter EODAD instantly.

Specifying DSORG=PS might make a difference.