Hi Scott, "... various ESMs ..." Does this mean: various External Security Managers?
Regards, David On 2019-11-27 12:03, scott Ford wrote: > We use one of the system subpool SP 231 for holding messages we build from > various ESMs. The customer asked if we could share SP231 across LPARs. > My take was no because I understood sp231 was unique until each LPAR . > > Scott > > On Wed, Nov 27, 2019 at 11:56 AM Allan Staller <[email protected]> > wrote: > >> Each LPAR has their own. >> >> SYSPLEX does not share (virtual or real) storage. >> Selected information is shared by XCF using CTC or Coupling Facility. >> >> HTH, >> >> -----Original Message----- >> From: IBM Mainframe Discussion List <[email protected]> On Behalf >> Of scott Ford >> Sent: Wednesday, November 27, 2019 10:33 AM >> To: [email protected] >> Subject: Sysplex >> >> I have a question related to storage subpool. If you running a sysplex do >> you share one set of subpool, I.e., sp 1 ,,etc. or does each LPAR have its >> own ? >> I assumed the later. >> >> >> Scott >> -- >> Scott Ford >> IDMWORKS >> z/OS Development >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, send email >> to [email protected] with the message: INFO IBM-MAIN >> ::DISCLAIMER:: >> ________________________________ >> The contents of this e-mail and any attachment(s) are confidential and >> intended for the named recipient(s) only. E-mail transmission is not >> guaranteed to be secure or error-free as information could be intercepted, >> corrupted, lost, destroyed, arrive late or incomplete, or may contain >> viruses in transmission. The e mail and its contents (with or without >> referred errors) shall therefore not attach any liability on the originator >> or HCL or its affiliates. Views or opinions, if any, presented in this >> email are solely those of the author and may not necessarily reflect the >> views or opinions of HCL or its affiliates. Any form of reproduction, >> dissemination, copying, disclosure, modification, distribution and / or >> publication of this message without the prior written consent of authorized >> representative of HCL is strictly prohibited. If you have received this >> email in error please delete it and notify the sender immediately. Before >> opening any email and/or attachments, please check them for viruses and >> other defects. >> ________________________________ >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO IBM-MAIN >> ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN