I didn't ignore them. If I did ignore them, I never would have written
the original email.

All the files are located on the LOCALMOD minidisk.

Where in the VMSECURE Rules manual does it mention running VMFBLD PPF
ZVM CP HCPGPI ( SERVICED   

?????

                

_______________________
Jim Hughes
603-271-5586
"Impossible is just an opinion."
"Your career is what you're paid for, your calling is what you're made
for."
"We cannot solve our problems with the same thinking we used when we
created them. Albert Einstein "

=>-----Original Message-----
=>From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED]
On
=>Behalf Of Imler, Steven J
=>Sent: Monday, July 10, 2006 4:24 PM
=>To: [email protected]
=>Subject: Re: VMSES Question
=>
=>Jim,
=>
=>YES! It matters!  You can't ignore these messages.
=>
=>If you installed the VM:Secure mods via the suggested instructions,
the
=>mods should have ended up you your LOCALMOD disk.
=>
=>Please review the VM:Secure TEXT deck installation procedure
(VM:Secure
=>Rules Facility Guide; Chapter 3) and ensure you have all 4 TEXT file
=>replacements on your LOCALMOD disk.
=>
=>Elsewise it looks like you neglected to run a:
=>
=>   VMFBLD PPF ppfname component HCPGPI ( SERVICED
=>
=>JR (Steven) Imler
=>CA
=>Senior Software Engineer
=>Tel:  +1 703 708 3479
=>Fax:  +1 703 708 3267
=>[EMAIL PROTECTED]
=>
=>
=>-----Original Message-----
=>From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED]
On
=>Behalf Of Hughes, Jim - OIT
=>Sent: Monday, July 10, 2006 04:00 PM
=>To: [email protected]
=>Subject: VMSES Question
=>
=>I downloaded UM31830, received, applied, and built a new cp.
=>
=>I also have VMSECURE's Rules facility installed.
=>
=>The VMFVIEW BUILD screen shows me this:
=>
=>**********************************************************************
**
=>****  PPFNAME: ZVM      COMPNAME: CP               BLDID: 5VMCPR20
****
=>**********************************************************************
**
=>****            Date: 07/10/06            Time: 15:48:27
****
=>**********************************************************************
**
=>BD:VMFBLD2180I There are 4 build requirements remaining
=>BD:VMFBLD2180I Build Requirements:
=>BD:            Bldlist   Object             Status
=>BD:VMFBLD2180I UNKNOWN   BLDLIST            MANUAL           Partid
=>BD:VMFBLD2180I                                               HCPRPG
TXE
=>BD:VMFBLD2180I                                               HCPRPD
TXE
=>BD:VMFBLD2180I                                               HCPRPW
TXE
=>BD:VMFBLD2180I                                               HCPRPI
TXE
=>
=>Do I need to be concerned?  I do not remember seeing these messages
when
=>I rebuilt CP following the VMSECURE Rules installation.
=>
=>I also have an unresolved external in the CP load map. It looks like
=>this:
=>
=>UNRESOLVED CROSS REFERENCE: SYMBOL TO ADCON CSECT, ASSEMBLED LOCATION
=>AND LENGTH
=>HCPRPL3N AT HCPRPD   000F3C AL4     HCPRPI   001890 AL4
=>
=>I am concerned since I do not remember seeing anything like this
during
=>my CP Build following the MSECURE Rules installation.
=>
=>Can someone help me understand what I need to tell VMSES to make the
=>VMFBLD2180I messages disappear?
=>
=>Thanks.
=>
=>_______________________
=>Jim Hughes
=>603-271-5586
=>"Impossible is just an opinion."
=>"Your career is what you're paid for, your calling is what you're made
=>for."
=>"We cannot solve our problems with the same thinking we used when we
=>created them. Albert Einstein "

Reply via email to