James,
what specifically did you mean by your first question:  Did you TN3270
to the ICC adapter IP # before ipl'ing.  
 
How do you TN3270 to the IP # before ipl'ing and AFTER OSA is reset with
the ipl?  We had the TN3270 session ready before the IPL and then the
OSA is reset in the IPL, so is there a timing issue with having to get
the TN3270 session ready again for the IPL to find it to send the SAIPL
screen?
 
 
 
We think the IOCP and system config are correct.
 
thanks again for your help
 
Joan M. Gerads 
Systems & Programming 
SCICOM Data Services, Ltd. 
10101 Bren Rd. East 
Minnetonka, MN  55343 
Direct: 952-936-4170 
Toll  Free: 1-800-488-9087 
Fax: 952-932-3936 


This e-mail message, including any attachments, is intended only for the
use of the recipient(s) and may contain privileged and confidential
information, including but not limited to information that is protected
under HIPAA or other state/federal privacy rules.  Any unauthorized
review; disclosure, copying, distribution or use is prohibited.  If you
have received this e-mail in error, please notify the sender immediately
by reply e-mail and destroy all copies of the original message. 

________________________________

From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of James M
Sent: Monday, May 21, 2007 12:54 PM
To: [email protected]
Subject: Re: VM CONSOLE Experts...I need your help


Joan-
There's a lot to consider & check.
Did you tn3270 to the ICC adapter IP # before ipl'ing?
Is your iocp correct?
Is your system config correct - console defined same as ipl device on
ICC def. 
Are your ICC definitions correct - valid ipl device & pc ip # specified
correctly
I'm using the hummingbird emulator w/o problems.
-James


On 5/21/07, Joan Gerads <[EMAIL PROTECTED]> wrote: 

        I have a couple more questions regarding setting up a VM console
through OSA-ICC. 

        z/VM version 5.2 -  
        IBM z9 2096 BC processor 1 LPAR 
        VM running multiple VSE guests 

        1)   is there any software restrictions as far as 3270 emulator
software running on the PC for the VM console to work on it?  We are
currently trying it with QWS Plus Version 4.0 (JollyGiant Software)?

        Is anyone else using that software? Or what is working for you? 

        2)  secondly, on the HMC screen for OSA Advanced Facilities,
'active sessions configuration ', there is a field called 'MIFID'.  In
the IBM Redbook example, this field is set to a 'C ' on a VM console
definition.  On our screen, our VM console session, it is set to a '1'
(the default?)....what exactly does ' C' mean? 

        On a trial IPL of VM this last weekend, we could not get the
OSA-ICC PC to come up as the VM console...I am pretty sure the system
configuration is correct...we can 'DISC' from the dummy tube and
'RECONNECT' on the PC.  We just have not figured out the VM IPL- how to
get it to come up on the OSA-ICC PC.

        Thanks again for all your help! 

        Joan M. Gerads 
        Systems & Programming 
        SCICOM Data Services, Ltd. 
        10101 Bren Rd. East 
        Minnetonka, MN  55343 
        Direct: 952-936-4170 
        Toll  Free: 1-800-488-9087 
        Fax: 952-932-3936 


        This e-mail message, including any attachments, is intended only
for the use of the recipient(s) and may contain privileged and
confidential information, including but not limited to information that
is protected under HIPAA or other state/federal privacy rules.  Any
unauthorized review; disclosure, copying, distribution or use is
prohibited.  If you have received this e-mail in error, please notify
the sender immediately by reply e-mail and destroy all copies of the
original message. 

        
































        z/VM version 5.2 -  
        IBM z9 2096 BC processor 1 LPAR 
        VM running multiple VSE guests 


        Two questions that I could use any advice, tips or tricks with: 


        We recently migrated to z/VM 5.2 and an IBM z9 BC processor: 

        1)    We recently switched our VM console from a dummy terminal
to an OSA connection.  We 'disc' VM on the dummy terminal and
reconnected the console on the PC.  That part worked fine.   We will not
be IPL'ing VM until this weekend so my question is: What do we need to
do to have the OSA console be recognized as the VM console during an IPL
of VM?   For the dummy terminal, we had the address hard assigned in the
system configuration under Console Definitions: Operator_Consoles....How
do you do that same thing with an OSA VM console?   An example would be
helpful.   Thanks 

        2)    We are planning on moving our VM packs from one set of
3390 Disk drives to another set of 3390 Disk drives.  Any hints on the
steps that should be followed to make this an easy transition?   Thanks
in advance 



        Joan M. Gerads 
        Systems & Programming 
        SCICOM Data Services, Ltd. 
        10101 Bren Rd. East 
        Minnetonka, MN  55343 
        Direct: 952-936-4170 
        Toll  Free: 1-800-488-9087 
        Fax: 952-932-3936 


        This e-mail message, including any attachments, is intended only
for the use of the recipient(s) and may contain privileged and
confidential information, including but not limited to information that
is protected under HIPAA or other state/federal privacy rules.  Any
unauthorized review; disclosure, copying, distribution or use is
prohibited.  If you have received this e-mail in error, please notify
the sender immediately by reply e-mail and destroy all copies of the
original message. 



Reply via email to