Hi,
We are trying to get a Hitachi Lightning 9970V DASD unit working. We can
attach the drives, CMS format them (with errors, but they appear to be
formatted), do DDR copies to them (no errors). The one thing we can't do
is write a label on them. When we run ICKDSF on the volumes we get:
init unit(7000) nvfy volid(nu7000)
INIT UNIT(7000) NVFY VOLID(NU7000)
ICK00700I DEVICE INFORMATION FOR 7000 IS CURRENTLY AS FOLLOWS:
PHYSICAL DEVICE = 3390
STORAGE CONTROLLER = 3990
STORAGE CONTROL DESCRIPTOR = E9
DEVICE DESCRIPTOR = 0A
ADDITIONAL DEVICE INFORMATION = 4A001B35
TRKS/CYL = 15, # PRIMARY CYLS = 3339
ICK04000I DEVICE IS IN SIMPLEX STATE
ICK00091I 7000 NED= 2105. .HTC.14.000000023257
ICK091I 7000 NED= 2105. .HTC.14.000000023257
ICK003D REPLY U TO ALTER VOLUME 7000 CONTENTS, ELSE T
u
U
ICK10710I I/O ERROR OCCURRED ON DEVICE 7000
CSW = 762290 0E40005C CCW = 1D762220 4000005C FILEMASK = 18
SENSE = 00090401 00000000 1D000000 01000000 67094C02 00F00F00 00004CE0
00000000
ICK31006I VOLUME LABEL CREATION FAILED
ICK30003I FUNCTION TERMINATED. CONDITION CODE IS 12
14:06:24 08/29/07
HCPERP6321I DASD 7000 AN OPERATION WAS TERMINATED BECAUSE RECORD
HCPERP6321I 0000000003 WAS NOT FOUND
HCPERP6300I SENSE DATA FORMAT = 00 MSG CODE = 00
HCPERP6301I CHANNEL COMMAND WORD COMMAND CODE = 86
HCPERP6302I SEEK ADDRESS = 000000000000
HCPERP6303I SENSE = 00090401 40000000 86000000 01000000 61495C03
HCPERP6303I 00F00F00 00004CE1 00000000
HCPERP6304I IRB = 00C04017 19320650 0E000050 00800009
HCPERP6305I USERID = MAINT
HCPERP2216I CHANNEL PATH ID = 70
HCPDAS537A DASD 7000 THE LABEL COULD NOT BE READ
A DITTO disk browse shows this for the disk:
DITTO/ESA for VM DB - Disk Browse
CYL-HD-REC 00000 00 000 Col 1
Format CHAR
Volume 7000 3390
Search limit
*
Rec Type Len
1...5...10....5...20....5...30....5...40....5...50....5...60
************** Begin of track Cyl:0 Hd:0 Reltrk:0
**************************
0 CNT 8 ........
DATA 8 ........
1 CNT 8 ........
KEY 4 IPL1
DATA 24 ........................
2 CNT 8 ........
KEY 4 IPL2
DATA 144 .... .......
...............................................
************** End of data on track
*******************************************
************** Begin of track Cyl:0 Hd:1 Reltrk:1
**************************
0 CNT 8 ........
Which confirms the record 3 not found message.
Our IOCP definition for the 9970V is:
CHPID PATH=70,TYPE=CNC
CHPID PATH=71,TYPE=CNC
CHPID PATH=72,TYPE=CNC
CHPID PATH=73,TYPE=CNC
CTL70 CNTLUNIT CUNUMBR=7001,PATH=(70,71),UNITADD=((00,256)), *
CUADD=0,UNIT=2105
CTL71 CNTLUNIT CUNUMBR=7101,PATH=(72,73),UNITADD=((00,256)), *
CUADD=1,UNIT=2105
IODEVICE ADDRESS=(7000,256),CUNUMBR=(7001,7101), *
UNIT=3390
Almost forgot, z/VM 3.1.0 service level 0402 running on an MP2000.
ICKDSF release 17, module dated 2006-11-07.
We specifically want to run as 2105 to flush out potential problems with
using 2105s with VSE before we (hopefully) move to a z9.
Hitachi says it is a problem with our definition of the drives. Seems
unlikely to me, but it beats me what the problem is.
So, does anyone have any ideas?
Peter
"People who say they have nothing to hide, nothing to fear about
providing their personal information, have no idea how information can
be misapplied out of context,"
Ann Cavoukian
Ontario Privacy Commissioner
The information transmitted is intended only for the person or entity to which
it is addressed and may contain confidential and/or privileged material. Any
review retransmission dissemination or other use of or taking of any action in
reliance upon this information by persons or entities other than the intended
recipient or delegate is strictly prohibited. If you received this in error
please contact the sender and delete the material from any computer. The
integrity and security of this message cannot by guaranteed on the Internet.
The Sender accepts no liability for the content of this e-mail or for the
consequences of any actions taken on basis of the information provided. The
recipient should check this e-mail and any attachments for the presence of
viruses. The sender accepts no liability for any damage caused by any virus
transmitted by this e-mail. This disclaimer is the property of the TTC and