For CMS purposes we have 2 sets of mdisks - 19x and 29x. The idea being
that when I install the new release I use the set not in use by the current
production CMS.

I am installing 530 and its time to use the 29x set of mdisks.
I have a ZVM ppf override to change the 19D to 29D  and to change the SES
$MAINT$ variable - using MAINT530 for the install.
I have also created 'new' segments so every release has its own set - For
EG. with CMS 23 we use HELPSE23 instead of HELPSEG.

Anyway all is OK except that when I try and build the HELPSE23 segment it
complains about NOT having a 19D.
What have I forgotten to change?

Here is the console:

bldsegs helpse23
VMFBLD2760I VMFBLD processing started
VMFSET2760I VMFSETUP processing started for SEGBLD ESASEGS
VMFSET2206W Modes A, B, C, and D are reserved for VMSES/E. The
            minidisks or directory ids at these modes should not
            be specified in the PPF. This conflict exists for
            minidisk or directory id 51D (D) specified in
            product parameter file SEGBLD PPF
VMFUTL2205I Minidisk|Directory Assignments:
            String    Mode  Stat  Vdev  Label/Directory
VMFUTL2205I APPLY     D      R/W  51D   MNT51D
VMFUTL2205I DELTA     D      R/W  51D   MNT51D
VMFUTL2205I BUILD     D      R/W  51D   MNT51D
VMFUTL2205I BASE      D      R/W  51D   MNT51D
VMFUTL2205I --------  A      R/W  191   DSK191
VMFUTL2205I --------  B      R/W  5E5   MNT5E5
VMFUTL2205I --------  C      R/O  DIR   VM:P696234G.HLASM.TBUILD
VMFUTL2205I --------  S      R/O  290   VM4290
VMFUTL2205I --------  Y/S    R/O  29E   MNT29E
VMFSET2760I VMFSETUP processing completed with warnings
VMFBLD1851I Reading build lists
VMFBLD2182I Identifying new build requirements
VMFBLD2182I New build requirements identified
VMFBLD1851I (1 of 1) VMFBDSEG processing SEGBLIST EXC00000 D, target is
BUILD
            51D (D)
VMFBDS2115I Validating segment HELPSE23
VMFBDS2002I A DEFSEG command will be issued for 1 segment(s).
VMFBDS2219I Processing object HELPSE23.SEGMENT
DMSACP113S Z(19D) not attached or invalid device address
DMSSFD653E Error executing ACCESS, rc=100
DMSGEN1279E Error(s) occurred during SEGGEN processing.
VMFBDS1965E The command, SEGGEN HELPSE23 PSEG A SYSTEM SEGID D2 ( NOTYPE,
faile
            with return code 32
VMFBLD1851E (1 of 1) VMFBDSEG completed with return code 100. Some objects
were
            not built
VMFBLD2180I There are 2 build requirements remaining
VMFBLD2760I VMFBLD processing completed unsuccessfully
Ready(00008); T=0.76/0.84 07:36:07

Reply via email to