I guess you need to change the HELP LSEG file, it contains 19D as address.

2007/9/14, Peter Rothman <[EMAIL PROTECTED]>:
>
> For CMS purposes we have 2 sets of mdisks - 19x and 29x. The idea being
> that when I install the new release I use the set not in use by the
> current
> production CMS.
>
> I am installing 530 and its time to use the 29x set of mdisks.
> I have a ZVM ppf override to change the 19D to 29D  and to change the SES
> $MAINT$ variable - using MAINT530 for the install.
> I have also created 'new' segments so every release has its own set - For
> EG. with CMS 23 we use HELPSE23 instead of HELPSEG.
>
> Anyway all is OK except that when I try and build the HELPSE23 segment it
> complains about NOT having a 19D.
> What have I forgotten to change?
>
> Here is the console:
>
> bldsegs helpse23
> VMFBLD2760I VMFBLD processing started
> VMFSET2760I VMFSETUP processing started for SEGBLD ESASEGS
> VMFSET2206W Modes A, B, C, and D are reserved for VMSES/E. The
>             minidisks or directory ids at these modes should not
>             be specified in the PPF. This conflict exists for
>             minidisk or directory id 51D (D) specified in
>             product parameter file SEGBLD PPF
> VMFUTL2205I Minidisk|Directory Assignments:
>             String    Mode  Stat  Vdev  Label/Directory
> VMFUTL2205I APPLY     D      R/W  51D   MNT51D
> VMFUTL2205I DELTA     D      R/W  51D   MNT51D
> VMFUTL2205I BUILD     D      R/W  51D   MNT51D
> VMFUTL2205I BASE      D      R/W  51D   MNT51D
> VMFUTL2205I --------  A      R/W  191   DSK191
> VMFUTL2205I --------  B      R/W  5E5   MNT5E5
> VMFUTL2205I --------  C      R/O  DIR   VM:P696234G.HLASM.TBUILD
> VMFUTL2205I --------  S      R/O  290   VM4290
> VMFUTL2205I --------  Y/S    R/O  29E   MNT29E
> VMFSET2760I VMFSETUP processing completed with warnings
> VMFBLD1851I Reading build lists
> VMFBLD2182I Identifying new build requirements
> VMFBLD2182I New build requirements identified
> VMFBLD1851I (1 of 1) VMFBDSEG processing SEGBLIST EXC00000 D, target is
> BUILD
>             51D (D)
> VMFBDS2115I Validating segment HELPSE23
> VMFBDS2002I A DEFSEG command will be issued for 1 segment(s).
> VMFBDS2219I Processing object HELPSE23.SEGMENT
> DMSACP113S Z(19D) not attached or invalid device address
> DMSSFD653E Error executing ACCESS, rc=100
> DMSGEN1279E Error(s) occurred during SEGGEN processing.
> VMFBDS1965E The command, SEGGEN HELPSE23 PSEG A SYSTEM SEGID D2 ( NOTYPE,
> faile
>             with return code 32
> VMFBLD1851E (1 of 1) VMFBDSEG completed with return code 100. Some objects
> were
>             not built
> VMFBLD2180I There are 2 build requirements remaining
> VMFBLD2760I VMFBLD processing completed unsuccessfully
> Ready(00008); T=0.76/0.84 07:36:07
>



-- 
Kris Buelens,
IBM Belgium, VM customer support

Reply via email to