I guess you need to change the HELP LSEG file, it contains 19D as address. 2007/9/14, Peter Rothman <[EMAIL PROTECTED]>: > > For CMS purposes we have 2 sets of mdisks - 19x and 29x. The idea being > that when I install the new release I use the set not in use by the > current > production CMS. > > I am installing 530 and its time to use the 29x set of mdisks. > I have a ZVM ppf override to change the 19D to 29D and to change the SES > $MAINT$ variable - using MAINT530 for the install. > I have also created 'new' segments so every release has its own set - For > EG. with CMS 23 we use HELPSE23 instead of HELPSEG. > > Anyway all is OK except that when I try and build the HELPSE23 segment it > complains about NOT having a 19D. > What have I forgotten to change? > > Here is the console: > > bldsegs helpse23 > VMFBLD2760I VMFBLD processing started > VMFSET2760I VMFSETUP processing started for SEGBLD ESASEGS > VMFSET2206W Modes A, B, C, and D are reserved for VMSES/E. The > minidisks or directory ids at these modes should not > be specified in the PPF. This conflict exists for > minidisk or directory id 51D (D) specified in > product parameter file SEGBLD PPF > VMFUTL2205I Minidisk|Directory Assignments: > String Mode Stat Vdev Label/Directory > VMFUTL2205I APPLY D R/W 51D MNT51D > VMFUTL2205I DELTA D R/W 51D MNT51D > VMFUTL2205I BUILD D R/W 51D MNT51D > VMFUTL2205I BASE D R/W 51D MNT51D > VMFUTL2205I -------- A R/W 191 DSK191 > VMFUTL2205I -------- B R/W 5E5 MNT5E5 > VMFUTL2205I -------- C R/O DIR VM:P696234G.HLASM.TBUILD > VMFUTL2205I -------- S R/O 290 VM4290 > VMFUTL2205I -------- Y/S R/O 29E MNT29E > VMFSET2760I VMFSETUP processing completed with warnings > VMFBLD1851I Reading build lists > VMFBLD2182I Identifying new build requirements > VMFBLD2182I New build requirements identified > VMFBLD1851I (1 of 1) VMFBDSEG processing SEGBLIST EXC00000 D, target is > BUILD > 51D (D) > VMFBDS2115I Validating segment HELPSE23 > VMFBDS2002I A DEFSEG command will be issued for 1 segment(s). > VMFBDS2219I Processing object HELPSE23.SEGMENT > DMSACP113S Z(19D) not attached or invalid device address > DMSSFD653E Error executing ACCESS, rc=100 > DMSGEN1279E Error(s) occurred during SEGGEN processing. > VMFBDS1965E The command, SEGGEN HELPSE23 PSEG A SYSTEM SEGID D2 ( NOTYPE, > faile > with return code 32 > VMFBLD1851E (1 of 1) VMFBDSEG completed with return code 100. Some objects > were > not built > VMFBLD2180I There are 2 build requirements remaining > VMFBLD2760I VMFBLD processing completed unsuccessfully > Ready(00008); T=0.76/0.84 07:36:07 >
-- Kris Buelens, IBM Belgium, VM customer support