No, you did not forget steps. Your procedure should work indeed. You can do it all on the running system, but, putting the new directory online must be done just before the shutdown, because (and I guess you know this) when the new directory is online, no minidisks can be linked anymore: CP will not be aware of the new volsers and responds for example: "Volume NEWRES not mounted"
2009/1/28 Mike Rydberg <[email protected]> > > I am assisting with a migration from a z9 to a new z10, which runs several VM > LPARs. One problem is that a couple of the VM systems use the same DASD > volsers on different device addresses. > > These volsers had been isolated by creative IOCP configuration on the z9, > segregating the duplicate volumes/devices from each of the VM LPARs, but the > problem is such that it needs to be resolved now, so that each VM system has > unique CP volsers. > > > > The VM system that we chose to re-label does not use dirmaint, so I'll be > hand editing of the USER DIRECT. > > > > It's been a long time since I have done this, so I would like to know if I > have forgotten any of the key steps to re-label all the CP Owned volumes from > a live system. > > Here's the steps that I think will accomplish this. > > > > While the system is up and running: > > > > - update the CP Owned list in the MAINT CF1/2 SYSTEM CONFIG > > > > - xedit a copy of the USER DIRECT and change the CP volsers on all the MDISK > statement to the new volsers. > > (ie: change /OLDRES/NEWRES/ *, c /OLDSPL/NEWSPL/ *, c /OLDPAG/NEWPAG/ *, c > /OLDW01/NEWW01/ *, etc) > > > > - use CPFMTXA to change the labels on all the old volsers to the new volsers. > This can be done after the system is shutdown, if that matters. > > > > - place the updated USER DIRECT online (DIRECTXA USER DIRECT), note that I'm > not sure if it matters whether this is done before or after the volume > re-label step. > > > > - Shutdown and IPL VM with the device address for NEWRES. > > > > I have backups of all the volumes already. We have other VM systems with > access to these DASD volumes for recovery if things don't go well or that can > assist in this task. > > > > Is there anything obvious with that I may have missed or a better order for > these steps? > > > > Thanks > > > > Mike > > > > > > -- Kris Buelens, IBM Belgium, VM customer support