On Tue, Nov 17, 2009 at 5:39 AM, Alan Altmark <[email protected]> wrote:

> Sorry.  I thought I knew what you meant.  :-)  A program interrupt loop is
> detected when there is a program check and the current PSW is the "same"
> as the Program New PSW.  This indicates that there is something wrong with
> Program New PSW or there's not a valid instruction at the address pointed
> to by the PNPSW.

I stand corrected. CP is not able to detect a program check in the
handler other than an invalid new PSW. If it's not wiped out, the my
bet would be on a BC-mode PSW. If CP D PSW ALL does not show you, a
TRACE PROG should.

Rob