Hello all,

I was adding a 2nd page volume LEPG2A (3390-3) to one of our newly installed 
z/VM 6.1 and I accidentally formatted cylinder 0 PERM. We are now getting 
alerts about "IEC606I VTOC INDEX DISABLED ON 5815,LEPG2A,142,00000000". The new 
Page volume is working on z/VM.

q alloc page
                EXTENT     EXTENT  TOTAL  PAGES   HIGH    %
VOLID  RDEV      START        END  PAGES IN USE   PAGE USED
------ ---- ---------- ---------- ------ ------ ------ ----
LEPG1A 5814          1       3338 600840      0      0   0%
LEPG2A 5815          1       3338 600840      0      0   0%
                                  ------ ------        ----
SUMMARY                            1174K      0          0%
USABLE                             1174K      0          0%

All our DASD storage is managed from the MVS side and I am guessing that it 
looks for the VTOC and alerts when it cannot find one. Can I use ICKDSF to put 
a valid VTOC back on the DASD? Are there any pointers on this subject that I 
can use to get more information on? Does Device Support facility's user guide 
all the information that I need to do the above.

Thank you,
Ashwin Bhemidhi
Texas Instruments Inc.


Reply via email to