here is an entry from today's log:

Sep 11 02:01:33 iglu kernel: SCSI disk error : host 1 channel 0 id 0 lun 0
return code = 2
Sep 11 02:01:33 iglu kernel: scsidisk I/O error: dev 08:21, sector 1572952
Sep 11 02:01:33 iglu kernel: EXT2-fs error (device md(9,0)):
ext2_read_inode: unable to read inode block - inode=98401, block=196619

it doesn't look like a software problem - i think we should start
considering hardware problems. these could include (from lightest to
heaviest):

1. loose cabling/controller card.
2. bad cable(s).
3. bad SCSI controller (are all disks sitting on the same controler, or
   the RAID ones are on their own controller?
4. bad SCSI disk.

omer/chen - could you check with compaq's (ligad's?) people what's their
policy for handling such problems? if it was up to me - i'd start checking
them by the order mentioned. first open the computer and tighten
cabling/controller, and if that doesn't help, start replacing parts until
the problem is fixed.

guy

"For world domination - press 1,
 or dial 0, and please hold, for the creator." -- nob o. dy


----------------------------------------------------------------------------