here is an entry from today's log: Sep 11 02:01:33 iglu kernel: SCSI disk error : host 1 channel 0 id 0 lun 0 return code = 2 Sep 11 02:01:33 iglu kernel: scsidisk I/O error: dev 08:21, sector 1572952 Sep 11 02:01:33 iglu kernel: EXT2-fs error (device md(9,0)): ext2_read_inode: unable to read inode block - inode=98401, block=196619 it doesn't look like a software problem - i think we should start considering hardware problems. these could include (from lightest to heaviest): 1. loose cabling/controller card. 2. bad cable(s). 3. bad SCSI controller (are all disks sitting on the same controler, or the RAID ones are on their own controller? 4. bad SCSI disk. omer/chen - could you check with compaq's (ligad's?) people what's their policy for handling such problems? if it was up to me - i'd start checking them by the order mentioned. first open the computer and tighten cabling/controller, and if that doesn't help, start replacing parts until the problem is fixed. guy "For world domination - press 1, or dial 0, and please hold, for the creator." -- nob o. dy ---------------------------------------------------------------------------- To unsubscribe, send a message to [EMAIL PROTECTED] Archives available at http://www.mail-archive.com/[email protected]/