On 16 Nov 1996 [EMAIL PROTECTED] wrote:

> 0./ Does anyone use Sparc Storage arrays. If so, what management
> software do you use, the storage Volume Manager s/w (I have version
> 2.1.1) or Online: DiskSuite? 
>

We tested Volume Manager once, but ran into the problem that it has its own
fsck. The consequence was that after a crash we lost all AFS files.  And with
the AFS fsck nothing worked. This was more or less in a hurry so I don't know
whether one could have come around the problem. 

DiskSuite however works - as it would on normal disks. I have heard that 
logged filesystems were problematic, but raid (for which we use it) works 
fine. We haven't tested mirrors. Anyway, you don't need DiskSuite to 
access the StorageArray disks.


 
> 2./ How do you configure your disks? What RAID level? I was thinking of
> either 5 or 0+1 for a pair of internal disks with the OS on them, and
> RAID 0 for the disks in the storage array for the afs partitions.
> Exactly how what use do people make of the volume Manager? (the
> configuration options seem endless).
>

RAID 5 on some of them, normal disks on others.

=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
Rainer Toebbicke    http://wwwcn1.cern.ch/~rtb -or- [EMAIL PROTECTED]  O__
European Laboratory for Particle Physics(CERN) - Geneva, Switzerland   > |
Phone: +41 22 767 8985       Fax: +41 22 767 7155                     ( )\( )