On Tue, Mar 17, 2015 at 08:43:02PM +0000, Konduru, Chandra wrote: > > > > -----Original Message----- > > From: Daniel Vetter [mailto:[email protected]] On Behalf Of Daniel > > Vetter > > Sent: Tuesday, March 17, 2015 7:22 AM > > To: Konduru, Chandra > > Cc: [email protected]; Conselvan De Oliveira, Ander; Vetter, > > Daniel > > Subject: Re: [Intel-gfx] [PATCH 19/21] drm/i915: Enable skylake panel > > fitting > > using skylake shared scalers > > > > On Sat, Mar 14, 2015 at 10:55:44PM -0700, Chandra Konduru wrote: > > > Modify skylake panel fitting implementation to use shared scalers. > > > > > > Signed-off-by: Chandra Konduru <[email protected]> > > > > Ah here's the real pfit state, and the scaler state is just readout. Still > > we recover > > this from the bios, I do think we need to make sure that at least the crtc > > scaler is > > correctly assigned. Can't we recompute the scaler state after readout to > > make > > sure it fits with pfit state here? > > -Daniel > > Crtc scaler can be computed from hw readout. As replied earlier, will be > making > changes to update crtc scaler_id and appropriately set the scaler_users.
When you add state readout suppoort for crtc scaler id, please also add corresponding self-check code to intel_pipe_config_compare. That way we can exercise all the fastboot code with normal igt testcases which massively improves automated test coverage. -Daniel -- Daniel Vetter Software Engineer, Intel Corporation http://blog.ffwll.ch _______________________________________________ Intel-gfx mailing list [email protected] http://lists.freedesktop.org/mailman/listinfo/intel-gfx