So in other words, I can't pass the hostname of the probed device?
Is there any variable that I can extract the hostname from with in the probe
and assign it to an arbitrary variable that I then can pass into the CLI
script?
__________________________________________________________
Andrey Gordon | Integrity Interactive | Network Engineer | +1.781.398.3518



> From: "Christopher L. Sweeney" <[EMAIL PROTECTED]>
> Reply-To: InterMapper Discussion <[email protected]>
> Date: Thu, 11 Dec 2008 10:04:06 -0500
> To: InterMapper Discussion <[email protected]>
> Subject: Re: [IM-Talk] Variables
> 
> At 11:15 AM -0500 12/10/08, Andrey Gordon wrote:
>> ${devicename} does not seem to work. I just get NOT FOUND when using that.
> 
> The macros you can pass to a command-line probe are:
> 
> ${ADDRESS} -- The IP address of the device
> ${PORT} -- The port of the device
> ${MESSAGE} -- The message as configured for the notifier
> ${STRIPPED_MESSAGE} -- Same as ${MESSAGE}, but with newlines,
> carriage returns, single quotes, and double quotes stripped.
> ${ESCAPED_MESSAGE} -- Same as ${MESSAGE}, but escaped as though it were a URL.
> 
> -- Christopher
> 
> -- 
> ================================================
> Christopher L. Sweeney
> Dartware, LLC
> http://www.dartware.com/
> ____________________________________________________________________
> List archives: 
> http://www.mail-archive.com/intermapper-talk%40list.dartware.com/
> To unsubscribe: send email to: [EMAIL PROTECTED]
> 

____________________________________________________________________
List archives: 
http://www.mail-archive.com/intermapper-talk%40list.dartware.com/
To unsubscribe: send email to: [EMAIL PROTECTED]

Reply via email to