So in other words, I can't pass the hostname of the probed device? Is there any variable that I can extract the hostname from with in the probe and assign it to an arbitrary variable that I then can pass into the CLI script? __________________________________________________________ Andrey Gordon | Integrity Interactive | Network Engineer | +1.781.398.3518
> From: "Christopher L. Sweeney" <[EMAIL PROTECTED]> > Reply-To: InterMapper Discussion <[email protected]> > Date: Thu, 11 Dec 2008 10:04:06 -0500 > To: InterMapper Discussion <[email protected]> > Subject: Re: [IM-Talk] Variables > > At 11:15 AM -0500 12/10/08, Andrey Gordon wrote: >> ${devicename} does not seem to work. I just get NOT FOUND when using that. > > The macros you can pass to a command-line probe are: > > ${ADDRESS} -- The IP address of the device > ${PORT} -- The port of the device > ${MESSAGE} -- The message as configured for the notifier > ${STRIPPED_MESSAGE} -- Same as ${MESSAGE}, but with newlines, > carriage returns, single quotes, and double quotes stripped. > ${ESCAPED_MESSAGE} -- Same as ${MESSAGE}, but escaped as though it were a URL. > > -- Christopher > > -- > ================================================ > Christopher L. Sweeney > Dartware, LLC > http://www.dartware.com/ > ____________________________________________________________________ > List archives: > http://www.mail-archive.com/intermapper-talk%40list.dartware.com/ > To unsubscribe: send email to: [EMAIL PROTECTED] > ____________________________________________________________________ List archives: http://www.mail-archive.com/intermapper-talk%40list.dartware.com/ To unsubscribe: send email to: [EMAIL PROTECTED]