Hey guys, I'm having the same problem as Tomasz detailed here: http://sourceforge.net/mailarchive/message.php?msg_name=fuili2%24ss%241%40ger.gmane.org
I have several Dell PowerEdge 1950 and 2950 servers, all exhibit the same behavior. `ipmitool sdr` says the power supplies are ok, even when one is dead (or unplugged). Overall system report says power is OK: localhost ~ # ipmitool sdr | grep "PS Redundancy" PS Redundancy | 0x02 | ok Specific query says power is bad: localhost ~ # ipmitool sdr type "Power Supply" Status | 64h | ok | 10.1 | Presence detected, Failure detected, Power Supply AC lost Status | 65h | ok | 10.2 | Presence detected PS Redundancy | 74h | ok | 7.1 | Redundancy Lost BTW, I applied the new patches from Dell and find the extra reporting features useful. However, it still says all is ok with `ipmitool sdr`. This looks like a bug in the sdr reporting, since it happens to myself using Dell hardware and to Tomasz who doesn't. Let me know if you need any other feedback/testing since I can easily reproduce the behavior. Thanks! ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ _______________________________________________ Ipmitool-devel mailing list Ipmitool-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/ipmitool-devel