Hey guys,
I'm having the same problem as Tomasz detailed here:
http://sourceforge.net/mailarchive/message.php?msg_name=fuili2%24ss%241%40ger.gmane.org
I have several Dell PowerEdge 1950 and 2950 servers, all exhibit the same
behavior. `ipmitool sdr` says the power supplies are ok, even when one is dead
(or unplugged).
Overall system report says power is OK:
localhost ~ # ipmitool sdr | grep "PS Redundancy"
PS Redundancy | 0x02 | ok
Specific query says power is bad:
localhost ~ # ipmitool sdr type "Power Supply"
Status | 64h | ok | 10.1 | Presence detected, Failure detected,
Power Supply AC lost
Status | 65h | ok | 10.2 | Presence detected
PS Redundancy | 74h | ok | 7.1 | Redundancy Lost
BTW, I applied the new patches from Dell and find the extra reporting features
useful. However, it still says all is ok with `ipmitool sdr`.
This looks like a bug in the sdr reporting, since it happens to myself using
Dell hardware and to Tomasz who doesn't.
Let me know if you need any other feedback/testing since I can easily reproduce
the behavior.
Thanks!
-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft
Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
_______________________________________________
Ipmitool-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/ipmitool-devel