Hey guys,

I'm having the same problem as Tomasz detailed here:
http://sourceforge.net/mailarchive/message.php?msg_name=fuili2%24ss%241%40ger.gmane.org

I have several Dell PowerEdge 1950 and 2950 servers, all exhibit the same 
behavior.  `ipmitool sdr` says the power supplies are ok, even when one is dead 
(or unplugged).

Overall system report says power is OK:
localhost ~ # ipmitool sdr | grep "PS Redundancy" 
PS Redundancy    | 0x02              | ok

Specific query says power is bad:
localhost ~ # ipmitool sdr type "Power Supply"                         
Status           | 64h | ok  | 10.1 | Presence detected, Failure detected, 
Power Supply AC lost
Status           | 65h | ok  | 10.2 | Presence detected
PS Redundancy    | 74h | ok  |  7.1 | Redundancy Lost

BTW, I applied the new patches from Dell and find the extra reporting features 
useful.  However, it still says all is ok with `ipmitool sdr`.

This looks like a bug in the sdr reporting, since it happens to myself using 
Dell hardware and to Tomasz who doesn't.

Let me know if you need any other feedback/testing since I can easily reproduce 
the behavior.