Hi Matjaž and list,

Matjaž Straus Istenič <[email protected]> writes:

> [OSPF problem with multiple interfaces holding the same link-local
> address]
>
> It looks a *bug* to me.

It is.  What hardware/software combo do you have this problem on?  Have
you opened a case with the vendor yet?

> Workaround is rather simple: use different link-local addresses on
> IPv6-enabled interfaces and you are safe.

That's simple until someone decided to make life easier by using
interface IDs that identify the router for the link-local addresses; I
personally have a tendency to opt for fe80::feed:<router number>/64, and
I've seen other people do similar things.  You bring one of these
machines into an existing network with that sort of addressing scheme,
and the rather simple workaround means that addressing scheme goes down
the drain.

Feel free to quote me on this if the vendor can't be bothered to
consider this a "real" problem:-)


Cheers,

    Benedikt

-- 
                         Business Grade IPv6
                    Consulting, Training, Projects

Benedikt Stockebrand, Dipl.-Inform.        http://www.stepladder-it.com/

Reply via email to