https://issues.apache.org/jira/browse/CALCITE-5990?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17775340#comment-17775340
 ] 

Mihai Budiu commented on CALCITE-5990:
--------------------------------------

I have a fix for this issue, but it needs a fix for [CALCITE-5921] first, so I 
will submit that one first.

> Explicit cast to numeric type doesn't check overflow
> ----------------------------------------------------
>
>                 Key: CALCITE-5990
>                 URL: https://issues.apache.org/jira/browse/CALCITE-5990
>             Project: Calcite
>          Issue Type: Bug
>          Components: core
>    Affects Versions: 1.35.0
>            Reporter: Runkang He
>            Assignee: Runkang He
>            Priority: Blocker
>             Fix For: 1.36.0
>
>
> Explicit cast to numeric type doesn't check overflow, and this issue can be 
> reproduced by sqlline:
> {code:sql}
> select cast(empno as tinyint), cast(130 as tinyint) from emps where 
> name='Alice'; -- empno is 130
> {code}
> The empno is INT type. The result is wrong:
> {code:sql}
> -126, -126{code}
> I think it should throw exception when overflow, instead of returning wrong 
> result to user.
> At last, this issue was found when to turn on runtime check for 
> CalciteSqlOperatorTest in CALCITE-5921.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to