Luca Burgazzoli commented on CAMEL-6616:
----------------------------------------
I did a little analysis using SmppProducerReconnectIntegrationTest +
seleniumsoftware simulator and so far the behavior is:
- if the first connection happens, the producer will try to reconnect if the
connection get lost
- if the first connection fails (server down, wrong host/port, wrong
credentials) the producer stops without retrying
So it would be nice to know:
- what are the incorrect parameters leading to an infinite loop (I know it is a
little late)
- what should be the behavior in case of failure of the first connection.
> On SMPP producer start if SMSC returns a negative bind response producer will
> get stuck in an infinite reconnect loop
> ---------------------------------------------------------------------------------------------------------------------
>
> Key: CAMEL-6616
> URL: https://issues.apache.org/jira/browse/CAMEL-6616
> Project: Camel
> Issue Type: Improvement
> Components: camel-smpp
> Affects Versions: 2.11.1
> Reporter: Mark Mc Kenna
> Fix For: Future
>
>
> On SMPP producer start if the SMSC returns a negative response on initial
> bind the Producer.start() method will get stuck in an infinite reconnect loop
> (assuming the SMSC is returning a negative response due to incorrect
> parameters)
--