Sebb updated NET-311:
---------------------

    Priority: Minor  (was: Blocker)

> FTPClient.protected Socket _openDataConnection_(int command, String arg) 
> returns null
> -------------------------------------------------------------------------------------
>
>                 Key: NET-311
>                 URL: https://issues.apache.org/jira/browse/NET-311
>             Project: Commons Net
>          Issue Type: Bug
>    Affects Versions: 2.0
>         Environment: Windows XP, but I would think not platform specific.
>            Reporter: Brent W.
>            Priority: Minor
>   Original Estimate: 0.08h
>  Remaining Estimate: 0.08h
>
>     protected Socket _openDataConnection_(int command, String arg)
>       throws IOException
>     {
>         Socket socket;
>         if (__dataConnectionMode != ACTIVE_LOCAL_DATA_CONNECTION_MODE &&
>                 __dataConnectionMode != PASSIVE_LOCAL_DATA_CONNECTION_MODE)
>             return null;
>         ....
>      }
> This if condition is impossible to satisfy.  Should be OR(||) instead of 
> AND(&&).
> __dataConnectionMode can not be set to 2 & 0 at the same time.

-- 