https://issues.apache.org/jira/browse/FLINK-7731?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16200208#comment-16200208
]
Gerard Garcia commented on FLINK-7731:
--------------------------------------
I tried that but it still doesn't work. I have been doing some debugging and it
seems to me that the timer never gets triggered. It may be that what is
happening is that the {{onProcessingTime}} callback is only triggered when
there are contents in the window state (all code snippets are from version
1.3.2):
org.apache.flink.streaming.runtime.operators.windowing.WindowOperator#onProcessingTime()
{code:java}
ACC contents = null;
if (windowState != null) {
contents = windowState.get();
}
if (contents != null) {
TriggerResult triggerResult =
triggerContext.onProcessingTime(timer.getTimestamp());
if (triggerResult.isFire()) {
emitWindowContents(triggerContext.window,
contents);
}
if (triggerResult.isPurge()) {
windowState.clear();
}
}
{code}
and that state is being cleared when the trigger result is type purge:
org.apache.flink.streaming.runtime.operators.windowing.WindowOperator#processElement()
{code:java}
TriggerResult triggerResult =
triggerContext.onElement(element);
if (triggerResult.isFire()) {
ACC contents = windowState.get();
if (contents == null) {
continue;
}
emitWindowContents(window, contents);
}
if (triggerResult.isPurge()) {
windowState.clear();
}
{code}
> Trigger on GlobalWindow does not clean state completely
> -------------------------------------------------------
>
> Key: FLINK-7731
> URL: https://issues.apache.org/jira/browse/FLINK-7731
> Project: Flink
> Issue Type: Bug
> Components: Core, DataStream API
> Affects Versions: 1.3.2
> Reporter: Gerard Garcia
> Priority: Minor
>
> I have an operator that consists of:
> CoGroup Datastream -> GlobalWindow -> CustomTrigger -> Apply function
> The custom trigger fires and purges the elements after it has received the
> expected number of elements (or when a timeout fires) from one of the streams
> and the apply function merges the elements with the ones received from the
> other stream. It appears that the state of the operator grows continuously so
> it seems it never gets completely cleaned.
> There is a discussion in
> http://apache-flink-user-mailing-list-archive.2336050.n4.nabble.com/Clean-GlobalWidnow-state-td15613.html
> that suggests that it may be a bug.
> This job reproduces the issue:
> https://github.com/GerardGarcia/flink-global-window-growing-state
--
This message was sent by Atlassian JIRA
(v6.4.14#64029)