tillrohrmann commented on a change in pull request #7568: [FLINK-11417] Make 
access to ExecutionGraph single threaded from JobMaster main thread
URL: https://github.com/apache/flink/pull/7568#discussion_r250609358
 
 

 ##########
 File path: 
flink-runtime/src/main/java/org/apache/flink/runtime/executiongraph/failover/FailoverRegion.java
 ##########
 @@ -152,10 +160,16 @@ private void cancel(final long 
globalModVersionOfFailover) {
                                        }
 
                                        final FutureUtils.ConjunctFuture<Void> 
allTerminal = FutureUtils.waitForAll(futures);
-                                       allTerminal.thenAcceptAsync(
-                                               (Void value) -> 
allVerticesInTerminalState(globalModVersionOfFailover),
-                                               executor);
-
+                                       final Consumer<Void> recoveryAction =
+                                               (Void value) -> 
allVerticesInTerminalState(globalModVersionOfFailover);
+
+                                       if (testExecutor == null) {
+                                               // branch for production code.
+                                               
allTerminal.thenAccept(recoveryAction);
+                                       } else {
+                                               // this branch should only be 
taken for some unit tests.
+                                               
allTerminal.thenAcceptAsync(recoveryAction, testExecutor);
 
 Review comment:
   Which are the unit tests and why do they need to be handled differently?

----------------------------------------------------------------
This is an automated message from the Apache Git Service.
To respond to the message, please log on GitHub and use the
URL above to go to the specific comment.
 
For queries about this service, please contact Infrastructure at:
[email protected]


With regards,
Apache Git Services

Reply via email to