https://issues.apache.org/jira/browse/FLINK-13073?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16877633#comment-16877633
 ] 

Louis Xu commented on FLINK-13073:
----------------------------------

You are welcome. I am looking forward to contributing more to flink. [~ykt836]

> BinaryRow in Blink runtime has wrong FIRST_BYTE_ZERO mask
> ---------------------------------------------------------
>
>                 Key: FLINK-13073
>                 URL: https://issues.apache.org/jira/browse/FLINK-13073
>             Project: Flink
>          Issue Type: Bug
>          Components: Table SQL / Runtime
>    Affects Versions: 1.9.0
>            Reporter: Louis Xu
>            Assignee: Louis Xu
>            Priority: Major
>              Labels: pull-request-available
>             Fix For: 1.9.0
>
>          Time Spent: 10m
>  Remaining Estimate: 0h
>
> BinaryRow which in blink runtime module has static constant named 
> FIRST_BYTE_ZERO, it's purpose is filter first byte。It should be 8 bytes with 
> 0xFFFFFFF0 in little endian or 0x0FFFFFFF in big endian, actually it only has 
> 4 bytes. It result in that 24-55 bit of null field can not be check。



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)