https://issues.apache.org/jira/browse/FLINK-13073?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16877732#comment-16877732
 ] 

Louis Xu commented on FLINK-13073:
----------------------------------

[~jark] [~lzljs3620320] [~ykt836] I find some problem when I review the code. 
It's because I'm not familiar with binary format when hex transform to binary. 
Sorry, I have fix the pr and pushed again. Welcome to review the new version.

> BinaryRow in Blink runtime has wrong FIRST_BYTE_ZERO mask
> ---------------------------------------------------------
>
>                 Key: FLINK-13073
>                 URL: https://issues.apache.org/jira/browse/FLINK-13073
>             Project: Flink
>          Issue Type: Bug
>          Components: Table SQL / Runtime
>    Affects Versions: 1.9.0
>            Reporter: Louis Xu
>            Assignee: Louis Xu
>            Priority: Major
>              Labels: pull-request-available
>             Fix For: 1.9.0
>
>          Time Spent: 10m
>  Remaining Estimate: 0h
>
> BinaryRow which in blink runtime module has static constant named 
> FIRST_BYTE_ZERO, it's purpose is to filter first byte。
> Use 0xFFF0 as a exsample:
> its binary sequence is: 1111111111110000。It has 2 problems:
>  # It can only skip 4 bits of header. If the header is big than 15, then any 
> return long value from pos 0 intersect with FIRST_BYTE_ZERO will not equal to 
> 0. Then will always return true.
>  # It only can check 8 bit(0-7) of null fields, which left 8-55 bit of null 
> field unchecked.



--