https://issues.apache.org/jira/browse/FLINK-21467?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17306999#comment-17306999
 ] 

Piotr Nowojski commented on FLINK-21467:
----------------------------------------

Thanks for the explanation [~kezhuw]. For me this will be a part of FLIP-147. 
Definitely if an operator has already finished it can not be restarted.

However please note that it's not only about unaligned checkpoints and 
{{MAX_WATERMARK}}. The same applies to {{endOfInput}} and/or aligned 
checkpoints. In all of those cases, if operator has finished before n'th 
checkpoint, when recovering from this n'th checkpoint this operator must remain 
finished.

> Document possible recommended usage of Bounded{One/Multi}Input.endInput and 
> emphasize that they could be called multiple times
> ------------------------------------------------------------------------------------------------------------------------------
>
>                 Key: FLINK-21467
>                 URL: https://issues.apache.org/jira/browse/FLINK-21467
>             Project: Flink
>          Issue Type: Improvement
>          Components: API / DataStream
>    Affects Versions: 1.13.0
>            Reporter: Kezhu Wang
>            Priority: Major
>
> It is too tempting to use these api, especially {{BoundedOneInput.endInput}}, 
> to commit final result before FLIP-147 delivered. And this will cause 
> re-commit after failover as [~gaoyunhaii] has pointed out in FLINK-21132.
> I have 
> [pointed|https://github.com/apache/iceberg/issues/2033#issuecomment-784153620]
>  this out in 
> [apache/iceberg#2033|https://github.com/apache/iceberg/issues/2033], please 
> correct me if I was wrong.
> cc [~aljoscha] [~pnowojski] [~roman_khachatryan]



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to