zentol commented on a change in pull request #16345:
URL: https://github.com/apache/flink/pull/16345#discussion_r662993913
##########
File path:
flink-rpc/flink-rpc-akka/src/main/java/org/apache/flink/runtime/rpc/akka/AkkaRpcService.java
##########
@@ -137,6 +138,13 @@ public AkkaRpcService(
captureAskCallstacks = configuration.captureAskCallStack();
+ // Akka always sets the threads context class loader to the class
loader with which it was
+ // loaded (i.e., the plugin class loader)
+ // we must ensure that the context class loader is set to the Flink
class loader when we
+ // call into Flink
+ // otherwise we could leak the plugin class loader or poison the
context class leader of
+ // external threads (because they inherit the current threads context
class loader)
+ internalExecutor = new
ContextClassLoaderCleaningExecutor(actorSystem.dispatcher());
Review comment:
its not at all about the lifecycle; please see the PR description, it
does into detail why this is important.
--