https://issues.apache.org/jira/browse/FLINK-26892?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17513831#comment-17513831
 ] 

Gyula Fora commented on FLINK-26892:
------------------------------------

The problem is that the wrong config stays there "forever". Even if we get the 
scheduled reconcile 15 secs later, that again will give a validation error and 
we are not going to observe anything.

> Observe current status before validating CR changes
> ---------------------------------------------------
>
>                 Key: FLINK-26892
>                 URL: https://issues.apache.org/jira/browse/FLINK-26892
>             Project: Flink
>          Issue Type: Improvement
>          Components: Kubernetes Operator
>            Reporter: Gyula Fora
>            Priority: Major
>             Fix For: kubernetes-operator-1.0.0
>
>
> Currently validation is the first step in the controller loop which means 
> that when there is a validation error we fail to observe the status of 
> currently running deployments.
> We should change the order of operations and observe before validation. 
> Furthermore observe should use the previous configuration not the one after 
> the CR change.



--
This message was sent by Atlassian Jira
(v8.20.1#820001)

Reply via email to