> ContinuousProcessingTimeTrigger最后一个定时器无法触发
> ------------------------------------------
>
> Key: FLINK-23378
> URL: https://issues.apache.org/jira/browse/FLINK-23378
> Project: Flink
> Issue Type: Bug
> Affects Versions: 1.12.3
> Reporter: frey
> Priority: Minor
> Labels: auto-deprioritized-major, pull-request-available,
> stale-minor
>
> 使用滚动窗口,时间语义为ProcessingTime时,修改默认触发器为ContinuousProcessingTimeTrigger后,最后一个定时器时间等于下一个窗口的起始时间,所以无法触发最后一个定时器的计算
> 可修改onProcessingTime中time=window.maxTimestamp()时FIRE
--