echauchot commented on code in PR #22985:
URL: https://github.com/apache/flink/pull/22985#discussion_r1321300535
##########
flink-core/src/main/java/org/apache/flink/configuration/JobManagerOptions.java:
##########
@@ -488,6 +488,23 @@ public enum SchedulerType {
code(SchedulerExecutionMode.REACTIVE.name()))
.build());
+ @Documentation.Section(Documentation.Sections.EXPERT_SCHEDULING)
+ public static final ConfigOption<Duration> SCHEDULER_SCALING_INTERVAL_MIN =
+ key("jobmanager.adaptive-scheduler.scaling-interval.min")
+ .durationType()
+ .defaultValue(Duration.ofSeconds(30))
+ // rescaling and let the user increase the value for high
workloads
+ .withDescription(
+ "Determines the minimum time (in seconds) between
scaling operations in reactive mode.");
Review Comment:
1. if the parameter value is passed by CLI as a String, will the duration be
parsed correctly with the correct timeUnit?
2. yes but new resources addition call that triggers the rescale (and the
cooldown period) only happens in reactive mode.
--
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.
To unsubscribe, e-mail: [email protected]
For queries about this service, please contact Infrastructure at:
[email protected]