snuyanzin commented on code in PR #26157:
URL: https://github.com/apache/flink/pull/26157#discussion_r1955222196


##########
flink-table/flink-table-planner/src/main/scala/org/apache/flink/table/planner/plan/utils/WindowUtil.scala:
##########
@@ -237,13 +245,25 @@ object WindowUtil {
         }
         val step = getOperandAsLong(windowCall.operands(2))
         val maxSize = getOperandAsLong(windowCall.operands(3))
+        if (step <= 0 || maxSize <= 0) {
+          throw new TableException(
+            "Only positive step and size constant for CUMULATE window 
descriptors are supported.")
+        }
+        if (maxSize % step != 0) {
+          throw new TableException(
+            "CUMULATE window requires size being an integral multiple of 
step.")
+        }
         new CumulativeWindowSpec(Duration.ofMillis(maxSize), 
Duration.ofMillis(step), offset)
       case FlinkSqlOperatorTable.SESSION =>
         val tableArgCall = windowCall.operands(0).asInstanceOf[RexTableArgCall]
         if (!tableArgCall.getOrderKeys.isEmpty) {
           throw new ValidationException("Session window TVF doesn't support 
order by clause.")
         }
         val gap = getOperandAsLong(windowCall.operands(2))
+        if (gap <= 0) {
+          throw new TableException(

Review Comment:
   Otherwise 
https://github.com/apache/flink/blob/cd0cfe42c15042a3c27a0c341416aa32c0d594b6/flink-table/flink-table-runtime/src/main/java/org/apache/flink/table/runtime/operators/window/groupwindow/assigners/SessionWindowAssigner.java#L47-L50



-- 