bharathgunapati commented on PR #58:
URL: 
https://github.com/apache/flink-connector-http/pull/58#issuecomment-6401576237

   @davidradl Thanks for the review. All three comments are addressed in the 
latest push, see the threads above.
   
   One more change that is not from the review: the token request had no 
timeout, and its HTTP client had no connect timeout. If the identity provider 
did not answer, the sink writer thread would wait forever. The token request 
now uses the connector's request timeout: `http.sink.request.timeout` for the 
sink and `http.source.lookup.request.timeout` for lookups. A timeout fails the 
request with a message that names the token endpoint. New tests in 
`RequestSubmitterOidcTest` and `OIDCAuthHeaderValuePreprocessorTest` cover this.
   
   I also added two lines to the Restrictions section: the token request does 
not use the proxy or TLS trust options, and it is bounded by the request 
timeout. Making the token request use the proxy and trust settings is a good 
follow-up for lookup and sink together.


-- 