Ramin Gharib created FLINK-41591:
------------------------------------

             Summary: PARSE_XML keeps only microseconds of a dateTime in 
1677-09-21 00:12:43
                 Key: FLINK-41591
                 URL: https://issues.apache.org/jira/browse/FLINK-41591
             Project: Flink
          Issue Type: Bug
          Components: Table SQL / Runtime
            Reporter: Ramin Gharib


A {{dateTime}} with digits below a microsecond keeps its nanoseconds if it is 
in the range of a nanosecond timestamp, from {{1677-09-21 00:12:43.145224192}} 
to {{2262-04-11 23:47:16.854775807}} UTC. In the first second of that range, 
PARSE_XML keeps only microseconds.

{code:sql}
SELECT x, CAST(PARSE_XML('<a 
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"; xsi:type="dateTime">' || 
x || '</a>')['a'] AS TIMESTAMP(9)) AS ts
FROM (VALUES ('1677-09-21T00:12:43.145224192'), 
('1677-09-21T00:12:43.999999999'), ('1677-09-21T00:12:44.000000001')) AS t(x);
{code}

||x||Expected||Actual||
|1677-09-21T00:12:43.145224192|1677-09-21 00:12:43.145224192|1677-09-21 
00:12:43.145224000|
|1677-09-21T00:12:43.999999999|1677-09-21 00:12:43.999999999|1677-09-21 
00:12:43.999999000|
|1677-09-21T00:12:44.000000001|1677-09-21 00:12:44.000000001|1677-09-21 
00:12:44.000000001|

The same in batch and streaming mode. The upper bound works: 
{{2262-04-11T23:47:16.854775807}} keeps its nanoseconds.

h3. Cause
{{BinaryVariantUtil#nanosSinceEpoch}} returns 
{{ChronoUnit.NANOS.between(Instant.EPOCH, instant)}}. For 00:12:43, the epoch 
second is -9223372037, and {{Instant#until}} multiplies it by 10^9 before it 
adds the nanoseconds of the second. The product overflows, although the sum 
fits into a {{long}}. The method throws, and {{XmlToVariantParser}} falls back 
to microseconds. From the code, {{BinaryVariantBuilder}} calls the same method 
for an {{Instant}} or a {{LocalDateTime}} without catching it, so it rejects 
the same second.

h3. Proposal
* Compute the count from the epoch second plus one and the nanoseconds minus 
10^9 when the epoch second is negative, so the intermediate product stays in 
range.
* Test the first and the last value of the range, and one nanosecond outside 
each.
* The documentation page "XML and VARIANT" now gives the range from 
{{1677-09-21 00:12:44}}. Restore the full range there with the fix.



--