https://issues.apache.org/jira/browse/HBASE-9420?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13773664#comment-13773664
]
Ted Yu commented on HBASE-9420:
-------------------------------
Without proper synchronization, syncedTillHere may be assigned incorrect value
due to concurrent execution of syncer(long txid) because we need to read its
value, perform max computation and assign back.
> Math.max() on syncedTillHere lacks synchronization
> --------------------------------------------------
>
> Key: HBASE-9420
> URL: https://issues.apache.org/jira/browse/HBASE-9420
> Project: HBase
> Issue Type: Bug
> Reporter: Ted Yu
> Assignee: Ted Yu
> Fix For: 0.98.0
>
> Attachments: 9420-v1.txt
>
>
> In FSHlog#syncer(), around line 1080:
> {code}
> this.syncedTillHere = Math.max(this.syncedTillHere, doneUpto);
> {code}
> Assignment to syncedTillHere after computing max value is not protected by
> proper synchronization.
--