https://issues.apache.org/jira/browse/HBASE-4052?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

ramkrishna.s.vasudevan updated HBASE-4052:
------------------------------------------

    Attachment: TestMasterRestartAfterDisablingTable.java

This is the test for the scenario 1
where the table state is DISABLED

> Enabling a table after master switch is not allowing table scan.  Throws 
> NotServingRegionException
> --------------------------------------------------------------------------------------------------
>
>                 Key: HBASE-4052
>                 URL: https://issues.apache.org/jira/browse/HBASE-4052
>             Project: HBase
>          Issue Type: Bug
>         Environment: Linux
>            Reporter: ramkrishna.s.vasudevan
>         Attachments: Disabled.bmp, TestMasterRestartAfterDisablingTable.java
>
>
> Following is the scenario:
> Start RS and Active and standby masters
> Create table and insert data.
> Disable the table.
> Stop the active master and switch to the standby master.
> Now enable the table.
> Do a scan on the enabled table.
> NotServingRegionException is Thrown.
> But the same works well when we dont switch the master.

--
This message is automatically generated by JIRA.
For more information on JIRA, see: http://www.atlassian.com/software/jira

        

Reply via email to