kinolaev opened a new pull request, #18507:
URL: https://github.com/apache/iceberg/pull/18507

   With `immediateTableUpdate=false`, records needing a table update get 
equality field IDs resolved against the `DynamicRecord` schema. 
`DynamicTableUpdateOperator` then switches the record to the table schema but 
keeps those IDs. When the two schemas number fields differently, the writer 
either fails with `Cannot write a schema with an empty group` or silently uses 
the wrong columns as the equality key. The operator now remaps equality field 
IDs by column name onto the table schema, honoring case sensitivity.
   
   Test plan: an input schema whose field IDs overlap the table's but map to 
different columns; assert each output equality ID names the same column in the 
output schema as in the input schema. Fails without the fix.
   
   ---
   **AI Disclosure**
   - Model: Claude Opus 5.5
   - Platform/Tool: Claude Code
   - Human Oversight: fully reviewed
   - Prompt Summary: Diagnose a Flink dynamic sink failure from a production 
log and fix equality field ID resolution after table schema updates.


-- 