stevenzwu commented on code in PR #6407:
URL: https://github.com/apache/iceberg/pull/6407#discussion_r1068333995


##########
flink/v1.16/flink/src/main/java/org/apache/iceberg/flink/source/FlinkInputFormat.java:
##########
@@ -79,15 +68,9 @@ public BaseStatistics getStatistics(BaseStatistics 
cachedStatistics) {
   @Override
   public FlinkInputSplit[] createInputSplits(int minNumSplits) throws 
IOException {
     // Called in Job manager, so it is OK to load table from catalog.
-    tableLoader.open();
     final ExecutorService workerPool =
         ThreadPools.newWorkerPool("iceberg-plan-worker-pool", 
context.planParallelism());
-    try (TableLoader loader = tableLoader) {
-      Table table = loader.loadTable();
-      return FlinkSplitPlanner.planInputSplits(table, context, workerPool);
-    } finally {
-      workerPool.shutdown();
-    }
+    return FlinkSplitPlanner.planInputSplits(table, context, workerPool);

Review Comment:
   yeah. using readonly table for reader function is fine.



-- 