https://issues.apache.org/jira/browse/IGNITE-13015?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17147624#comment-17147624
 ] 

Anton Vinogradov commented on IGNITE-13015:
-------------------------------------------

Merged to master.
Thanks for your contribution.

> Use nano time in node failure detection.
> ----------------------------------------
>
>                 Key: IGNITE-13015
>                 URL: https://issues.apache.org/jira/browse/IGNITE-13015
>             Project: Ignite
>          Issue Type: Improvement
>    Affects Versions: 2.8.1
>            Reporter: Vladimir Steshin
>            Assignee: Vladimir Steshin
>            Priority: Minor
>              Labels: iep-45
>             Fix For: 2.9
>
>          Time Spent: 40m
>  Remaining Estimate: 0h
>
> Make sure node failure detection do not use:
> {code:java}
> System.currentTimeMillis()
> and
> IgniteUtils.currentTimeMillis()
> {code}
> We should use nano time instead. Disadventages of current impl.:
> 1)    System time has no quarantine of strict forward movement. System time 
> can be adjusted, synchronized by NTP as example. This can lead to incorrect 
> and negative delays.
> 2)     IgniteUtils.currentTimeMillis() is granulated by 10ms
> *To fix*:
> {code:java}ServerImpl.lastRingMsgReceivedTime{code} should be nano.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to