Todd Lipcon created KUDU-1380:
---------------------------------

             Summary: Scanners rewind to beginning of the tablet on 
SERVER_TOO_BUSY
                 Key: KUDU-1380
                 URL: https://issues.apache.org/jira/browse/KUDU-1380
             Project: Kudu
          Issue Type: Bug
    Affects Versions: 0.7.1
            Reporter: Todd Lipcon
            Priority: Blocker


When a scanner receives ERROR_SERVER_TOO_BUSY from an overloaded TS, the 
CanBeRetried() function indicates that it is safe to retry. However, this ends 
up calling through to ReopenCurrentTablet() which rewinds back to the start of 
the tablet in the case that the scan wasn't marked as fault-tolerant.

In the case of a lot of concurrent TPCH Q6 queries via Impala, this ended up 
resulting in "never-ending" queries - each scanner was likely to hit the 
occasional TOO_BUSY error and start back at the beginning.



--