https://issues.apache.org/jira/browse/MESOS-1571?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=14055427#comment-14055427
 ] 

Niklas Quarfot Nielsen commented on MESOS-1571:
-----------------------------------------------

[~tstclair] +1

> Signal escalation timeout is not configurable
> ---------------------------------------------
>
>                 Key: MESOS-1571
>                 URL: https://issues.apache.org/jira/browse/MESOS-1571
>             Project: Mesos
>          Issue Type: Bug
>            Reporter: Niklas Quarfot Nielsen
>
> Even though the executor shutdown grace period is set to a larger interval, 
> the signal escalation timeout will still be 3 seconds. It should either be 
> configurable or dependent on EXECUTOR_SHUTDOWN_GRACE_PERIOD.
> Thoughts?



--
This message was sent by Atlassian JIRA